Login / Register
Add a review
Log in
Sign UP
[bws_google_captcha]

this indicator shows market profiles on the graph, from any random place, for any arbitrary duration.

Create a rectangle on the graph, and this rectangle will automatically be full of the profile. Change the size of the rectangle or move it – the profile will automatically follow the modifications.

The indicator will be controlled using buttons and fields for inputting parameters and is stored by the indicator individually for every phase.

In the lower right corner of the graph window there is a pop- up AP button of the main menu, which is divided into two halves. Clicking on the left half switches groups of control buttons, clicking on the right half switches groups of fields for entering parameters.

  • AS – manual or automatic mode for building profiles.
  • MD-profile modes:
    • normal profile.
    • profile with a tint of the Delta.
    • the profile of the difference between the volumes of purchases and sales, that is, the profile of the Delta.
    • the profile of open interest obtained mathematically by preliminary sequential zeroing of mutually absorbing volumes.
    • the TPO profile.
  • CD-drawing profiles as a contour line.
  • PS-summary profile: right / left / disabled.
  • AT-type of cost zone:
    • normal distribution from the POC level.
    • distribution of the volume traded in the profile.
  • PE-continuation of the POC level in the form of a beam on / off.
  • EX-profile extremes: peaks / troughs / peaks and troughs / disabled.
  • PC – display of profiles based on volume comparison at POC levels.
  • CT values on profile clusters are enabled / disabled.
  • BT-labels above and below the profile are enabled / disabled.
  • BV-profile frame on / off.
  • VV-volume histogram bars are enabled / disabled.
  • SM-in this mode, profiles will only be displayed in the period and position in which they were created.
  • VT-volume type:
    • teak (VT).
    • real, if any, broadcast from the broker (VR).
    • excluding volume (VN).
  • PF-dynamic floating profile, profiles are arranged from right to left, starting from the current candle, with an offset to the right by one candle.
  • PA-alert:
    • for POC (PA).
    • for the cost zone (AA).
    • disabled (NA).
  • RS-resets parameters to default values, resets only for the current timeframe.
  • RT-apply parameters from the current timeframe to all other timeframes of this trading symbol.
  • DR-by default, the balance and delta are calculated from the point of view of market orders, this option activates the calculation mode from the point of view of limit orders.
  • FD-enables / disables the color fading effect.
  • LM-multiple modes for the TPO profile.
  • LT-enables / disables binding of TPO profile letters to date/time.

[spoiler title=”Read More…”]

  • normal profile.
  • profile with a tint of the Delta.
  • the profile of the difference between the volumes of purchases and sales, that is, the profile of the Delta.
  • the profile of open interest obtained mathematically by preliminary sequential zeroing of mutually absorbing volumes.
  • the TPO profile.
  • normal distribution from the POC level.
  • distribution of the volume traded in the profile.
  • teak (VT).
  • real, if any, broadcast from the broker (VR).
  • excluding volume (VN).
  • for POC (PA).
  • for the cost zone (AA).
  • disabled (NA).

  • PSP-fixed step of the profile calculation grid, set in “old” points, the value 0.1 corresponds to one ” new ” point.
  • PSPP-dynamic step of the profile calculation grid, set in pixels of the monitor.
  • Price Area – the size of the cost zone as a percentage.
  • Init Balance – the length of the initial balance profile as a percentage of the length of the main profile.
  • Period-profiles are aligned with the period specified in candlesticks, from right to left, starting from the current candle.
  • Offset – offset in candlesticks, can have a positive and negative value.
  • Lenght – the length of the profile in pixels of the monitor, which, regardless of the capture area, will not exceed the specified value.
  • Contrast – the contrast of the Delta values range from 1 to 4.
  • Begin time / bar – the initial time (or candle number) of the total profile, values not exceeding 1440 are perceived by the indicator as an indication of the candle number.
  • Finish time / bar – the final time (or candle number) of the total profile, values not exceeding 1440 are perceived by the indicator as an indication of the candle number.

  • quantitylimit – the maximum allowed number of profiles, including the total.
  • timingrefresh – update timing in milliseconds.
  • rectangleprefix-prefix of the reference rectangle name.

The other input variables relate to the color, font size, and line thickness settings, and their purpose is made clear by their name.

[/spoiler]

Add review
Reviews ( 0 ):